• English
  • 日本語
  • 한국어
  • Español
  • English
  • 日本語
  • 한국어
  • Español

PRODUCT



TMLONG leads to a simpler, smoother and more efficient automation system with leading technology. We can meet various special design requirements of different manufacturing industries. We are committed to the electric linear push rod system which is more convenient for end consumers and industrial manufacturers. Please refer to the more detailed product information below to learn how TMLONG's products enable manufacturers to create revolutionary high-quality end products.


图片展示

U12

U12

Select the number of specifications

Please check the product information you want!

Product Detail

U12 Side wall ventilation wall electric push rod for exhaust. This actuator is specially designed to open and close the agricultural air inlet, and is widely used in animal husbandry and breeding plants to adjust the air quality of farms with a complete set of environmental ventilation control system. U12 has a starting weight of 450kg, a power capacity of 350kg and a travel range of 200-1200mm.

  1. Installation details
  1. Actuator
  2. Installation unit a
  3. Installation unit b
  4. bolt

Step 1: Select an installation position supported by the structural frame of the building. The installation unit uses bolts. Note: Figure 2.1 shows some ways to install U12 on the wall. Other methods are possible and may need to be based on different wall conditions. (that is, close to the cement wall).


Step 2: Install hand winch, bracket, pulley, etc. Ensure that all cables will not interfere with the normal operation of doors and windows. Note: Make sure all pulleys are aligned with each other, otherwise the cable and pulleys will fail prematurely.

Step 3: Connect the curtain cable to the actuator. We suggest threading the cable and fixing it with a cable clamp. See Figure 2.2. When connecting the cable, make sure that the drive is in the closed position (not extended). This will ensure that the manual winch has enough cables to allow the operation of the air inlet.

Step 4: Tighten the slack in the cable with a hand winch until all entrances are completely closed and sealed. Place a cable clamp or tape on the cable near the hand winch to ensure that the cable will not be tightened after this point. Which may damage the building or entrance settings). See figure 2.3.


Step 5: If feedback control of potentiometer is used, the calibration control shall follow its instructions.


  1. Connection mode of 1.U12 ventilation actuator

Warning: Please cut off the power supply before wiring, and the wiring is correct!

(1) Motor wiring

120/220VAC


24/36/48VDC


(2) Potentiometer connection

Warning: Do not supply 120/230V power to the potentiometer connection, which will destroy the potentiometer immediately.

2. Adjustment of travel and potentiometer

(1) Adjust the stroke

  • loose a screw
  • Turn the upper cam to adjust; Clockwise direction+travel, counterclockwise direction-travel

4. Pulley configuration

There are many different possible pulley arrangements that can affect the maximum load and rate at which the air inlet opens and closes.

Figures 4.1 to 4.5 show some different options available.

Warning: The head bracket must be correctly aligned with the actuator, otherwise the actuator will fail.


7. Building layout

U12 can be installed vertically or horizontally on the wall or on the ceiling. These different import systems and building configurations. The following list shows some of the more common installation locations. See Figure 5.1 -5.2.

Note: U12 dynamic load capacity is 3500 n; However, unless all pulleys, pulley brackets, cables and winches can bear this load, you should not use its maximum load to load the loader group. In addition, for such a large load, extra precautions must be taken to ensure that all brackets are properly fixed on the building and the building structure can bear the load. The friction of pulley, static pressure and gust should also be considered, which will have a great impact on the load.

No comment

Product Detail

U12 Side wall ventilation wall electric push rod for exhaust. This actuator is specially designed to open and close the agricultural air inlet, and is widely used in animal husbandry and breeding plants to adjust the air quality of farms with a complete set of environmental ventilation control system. U12 has a starting weight of 450kg, a power capacity of 350kg and a travel range of 200-1200mm.

  1. Installation details
  1. Actuator
  2. Installation unit a
  3. Installation unit b
  4. bolt

Step 1: Select an installation position supported by the structural frame of the building. The installation unit uses bolts. Note: Figure 2.1 shows some ways to install U12 on the wall. Other methods are possible and may need to be based on different wall conditions. (that is, close to the cement wall).


Step 2: Install hand winch, bracket, pulley, etc. Ensure that all cables will not interfere with the normal operation of doors and windows. Note: Make sure all pulleys are aligned with each other, otherwise the cable and pulleys will fail prematurely.

Step 3: Connect the curtain cable to the actuator. We suggest threading the cable and fixing it with a cable clamp. See Figure 2.2. When connecting the cable, make sure that the drive is in the closed position (not extended). This will ensure that the manual winch has enough cables to allow the operation of the air inlet.

Step 4: Tighten the slack in the cable with a hand winch until all entrances are completely closed and sealed. Place a cable clamp or tape on the cable near the hand winch to ensure that the cable will not be tightened after this point. Which may damage the building or entrance settings). See figure 2.3.


Step 5: If feedback control of potentiometer is used, the calibration control shall follow its instructions.


  1. Connection mode of 1.U12 ventilation actuator

Warning: Please cut off the power supply before wiring, and the wiring is correct!

(1) Motor wiring

120/220VAC


24/36/48VDC


(2) Potentiometer connection

Warning: Do not supply 120/230V power to the potentiometer connection, which will destroy the potentiometer immediately.

2. Adjustment of travel and potentiometer

(1) Adjust the stroke

  • loose a screw
  • Turn the upper cam to adjust; Clockwise direction+travel, counterclockwise direction-travel

4. Pulley configuration

There are many different possible pulley arrangements that can affect the maximum load and rate at which the air inlet opens and closes.

Figures 4.1 to 4.5 show some different options available.

Warning: The head bracket must be correctly aligned with the actuator, otherwise the actuator will fail.


7. Building layout

U12 can be installed vertically or horizontally on the wall or on the ceiling. These different import systems and building configurations. The following list shows some of the more common installation locations. See Figure 5.1 -5.2.

Note: U12 dynamic load capacity is 3500 n; However, unless all pulleys, pulley brackets, cables and winches can bear this load, you should not use its maximum load to load the loader group. In addition, for such a large load, extra precautions must be taken to ensure that all brackets are properly fixed on the building and the building structure can bear the load. The friction of pulley, static pressure and gust should also be considered, which will have a great impact on the load.

U12
Long press to look detail
Long by picture save/share
INQUIRY

Online inquiry MORE+
  • (full) Name *

  • Telephone *

  • Email *

  • Describe

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully
INQUIRY

Online inquiry MORE+
  • (full) Name *

  • Telephone *

  • Email *

  • Describe

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

+86 135 0282 0175  Mr. Yang

+86 136 6982 4676  Mr. Zhong

tml@tmlong-linear-actuator.com

+86 769-3880 8976 

Floor 5, Building 1, No.3 Chongke Road, shipai town, Dongguan

分类标题
分类标题
分类标题
分类标题

Start Your Project

  • Name

  • E-mail

  • Message

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Share to

+86 135 0282 0175 Mr. Yang

+86 136 6982 4676  Mr. Zhong

tml@tmlong-linear-actuator.com

+86 769-3880 8976 

Floor 5, Building 1, No.3 Chongke Road, shipai town, Dongguan

Share to

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了